Gardner Denver 0.7m3/min - 145m3/min Desiccant Dryer

Gardner Denver 0.7m3/min - 145m3/min Desiccant Dryer

Gardner Denver 0.7m3/min - 145m3/min Desiccant Dryer

ardner Denver blast heat regeneration adsorption dryer adopts the principle of blast heating to complete the high-efficiency compressed air drying work. Greatly save the loss of compressed air and save energy.

The blower extracts ambient air, and after heating by an external electric heater, the hot air enters the regeneration tower for heating and regeneration of the adsorbent.

After a period of thermal regeneration, turn off the heater, use a blower to cold blow regeneration and cool down;

When the temperature of the adsorption tower is reduced to a certain point, the dry gas at the outlet of the working tower is used to regenerate the regeneration tower by cold blowing, and the average gas consumption in the cycle is ≤3%, so as to finally complete the regeneration of the adsorbent in the regeneration tower.

When the outlet air quality requirements are not high (such as atmospheric dew point ≤-40°C) or when the ambient temperature is low, only the blower can be used for cold blowing regeneration without introducing dry gas at the outlet of the working tower, so there is no regeneration gas consumption (at this time, the regeneration gas consumption is zero).

Gardner Denver 0.7m3/min - 145m3/min Desiccant Dryer

ardner Denver blast heat regeneration adsorption dryer adopts the principle of blast heating to complete the high-efficiency compressed air drying work. Greatly save the loss of compressed air and save energy.

The blower extracts ambient air, and after heating by an external electric heater, the hot air enters the regeneration tower for heating and regeneration of the adsorbent.

After a period of thermal regeneration, turn off the heater, use a blower to cold blow regeneration and cool down;

When the temperature of the adsorption tower is reduced to a certain point, the dry gas at the outlet of the working tower is used to regenerate the regeneration tower by cold blowing, and the average gas consumption in the cycle is ≤3%, so as to finally complete the regeneration of the adsorbent in the regeneration tower.

When the outlet air quality requirements are not high (such as atmospheric dew point ≤-40°C) or when the ambient temperature is low, only the blower can be used for cold blowing regeneration without introducing dry gas at the outlet of the working tower, so there is no regeneration gas consumption (at this time, the regeneration gas consumption is zero).